W&T Electronics Co. Ltd
|
Place of Origin: | Zhejiang, China (Mainland) |
Add to My Favorites | |
HiSupplier Escrow |
36W NiCa or NiMH batteries charger,can charge 2 to12 NiMH or NiCD cells in series, desktop type
Quick Detail:
Competitive Advantage:
High efficiency power(Level VI)
Meets "ENERGY STAR" program requirement
Over voltage protection
Over load & short circuit protection
100% full load burn-in test
Application:
It’s suitable for an extremely wide range of applications, including:
• Tablet/Mid charger
• Li-lon/Ni-mh/Ni-hydrogen/Lead-acid battery
• printer
• Digital camera
• Electronics Toy
• Hard disk drive
• Audio & Video product
• Small Household appliance
• Automotive charger
• Protable car battery charger
• Trickle battery charger
Specification datasheet:
INPUT | Voltage | 90-264VAC universal full range | |||||||
Frequency | 47-63Hz | ||||||||
Current | 1.25A@100V AC input, full load condition | ||||||||
Inrush Current | 40A@115V , 60A@230V AC input.Cold start at 25 ambient | ||||||||
Leakage Current | 1.25A@ 264V AC input | ||||||||
OUTPUT | PART NO. | AD36WC4.5 | AD36WC06 | AD36WC09 | AD36WC12 | AD36WC15 | AD36WC18 | AD36WC24 | AD36WC48 |
Voltage | 4.5V | 6V | 9.0V | 12.0V | 15V | 18V | 24V | 42V | |
Max Load | 0-5.0A | 0-5.0A | 0-4.0A | 0-3.0A | 0-2.4A | 0-2.0A | 0-1.5A | 0-0.75A | |
Output Tolerance | ±5% | ±5% | ±5% | ±5% | ±5% | ±5% | ±5% | ±5% | |
Ripple Noise(MAX) | 50mV | 50mV | 90mV | 120mV | 160mV | 200mV | 240mV | 240mV | |
Efficiency(MIN) | ≥65% | ≥65% | ≥75% | ≥75% | ≥75% | ≥75% | ≥75% | ≥75% | |
Output MAX | 36W | 36W | 36W | 36W | 36W | 36W | 36W | 36W | |
PROTECTION | Over Voltage | over 120%150 max | |||||||
Shutdown and latch off, recover after re-start up | |||||||||
Over Load & | When power supply over 105%150 max load or short circuit acted,powr supply will be shutdown and recover automatically after the fault is removed | ||||||||
Over Temperature | Over 95,the power supply will shutdown. | ||||||||
ENIRONMENT | Temperature | Operating:-2070;De-rating:4570:2.5%/;Storage:-40+85 | |||||||
Humidity | Operating: 20%90% RH(non condensing);Storage:10%95% RH(non condensing) | ||||||||
SAFETY | Withstand voltage | I/P-O/P:3KVAC,I/P-PE:1.5KVAC,O/P-PE:0.5KVAC,1 minute | |||||||
Isolation resistance | I/P-O/P,I/P-FG,O/P-FG>100MΩ/500VDC at 25/70% RH | ||||||||
Safety standard | UL 60950-1 2nd,CSA C22.2 No.60950-1-07 2nd,TU EN 60950-1:2006, | ||||||||
EMC | EMI | EN 55022 CLASS B,FCC CFR 47 PART 15 CLASS B,CNS 13438 CLASS B | |||||||
Compliance to EN61000-3-2 CLASS D,EN61000-3-3 | |||||||||
EMS | EN55024:EN61000-4-2,3,4,5,6,8,11 | ||||||||
OTHERS | Cooling | Natural Cooling | |||||||
M.T.B.F. | 100K hours | ||||||||
Dimension | 116x48x28mm ( L*W*H ) K-018-CABLE | ||||||||
Packing | N.W.:70g/1pc; 15pcs/1.05kg CUFT/1 CTN | ||||||||
|
|
|
Mechanical spec